Technical Overview
The Cat7 Copper SFTP (Shielded Foil Twisted Pair) Patch Cable is a premium enterprise-grade networking interconnect engineered for global export, fully complying with ISO/IEC 11801 Class F and EN 50173-1 specifications. Constructed with 23AWG solid oxygen-free copper (OFC) conductors and dual-layer shielding (foil per pair + overall braid), this patch cable delivers unmatched 600MHz bandwidth and supports 10Gbps transmission at full 100m, 40Gbps at 50m, and 100Gbps at 15m—setting a new benchmark for high-speed, interference-resistant connectivity. Optimized for mission-critical applications in data centers, industrial automation, and premium commercial/residential projects worldwide, its robust SFTP structure ensures zero signal degradation in extreme EMI environments while meeting global safety and environmental standards (RoHS 2.0, REACH, UL/ETL). The lightweight yet durable design reduces international logistics costs, making it a top choice for export markets demanding future-proof, low-latency networking solutions.
Key Technical Specifications
1. Transmission Performance Parameters
Bandwidth: 600MHz (Compliance Standard: ISO/IEC 11801 Class F, EN 50173-1 Cat7)
Data Rate: 10Gbps (100m), 40Gbps (50m), 100Gbps (15m) (Compliance Standard: IEEE 802.3ba, IEEE 802.3bm)
Characteristic Impedance: 100Ω ± 15% (1-600MHz) (Compliance Standard: IEC 61156-7)
Insertion Loss (IL): ≤ 28.5dB @ 600MHz (100m) (Compliance Standard: ISO/IEC 11801 Class F)
Return Loss (RL): ≥ 24dB @ 600MHz (Compliance Standard: EN 50173-1)
Near-End Crosstalk (NEXT): ≤ -65.3dB @ 600MHz (Compliance Standard: IEC 61156-7)
Far-End Crosstalk (FEXT): ≤ -62.4dB @ 600MHz (Compliance Standard: ISO/IEC 11801)
Alien Crosstalk (AXT): ≤ -60.1dB @ 600MHz (Compliance Standard: EN 50173-1 Annex E)
DC Loop Resistance: ≤ 7.5Ω/100m (Compliance Standard: IEC 61156-7)
Insulation Resistance: ≥ 100MΩ/km @ 20°C (Compliance Standard: EN 50173-1)
23AWG Oxygen-Free Copper Conductors: 99.99% pure OFC with 0.57mm diameter, featuring precision twist pitch (5.2 twists per inch) and pair-to-pair twist offset to minimize signal dispersion—critical for supporting 100Gbps short-reach transmission.
Precision Shielded RJ45 Connectors: 50-micron gold-plated phosphor bronze contacts with 3-point contact geometry, rated for 10,000+ mating cycles; 360° tinned copper shielding collar for continuous EMI protection, compliant with IEC 60603-7-5.
PoE++ Compatibility: Supports IEEE 802.3bt (PoE++) with 90W power delivery (4-pair transmission) and ≤ 2.8Ω conductor resistance, enabling powering of high-demand devices (4K PTZ cameras, industrial sensors, 5G small cells) in export markets.
2. SFTP Shielding Technology & Signal Integrity
Dual-Layer Shielding Architecture:
Primary Shield: 0.04mm aluminum polyester foil (per twisted pair) with 100% coverage and tinned copper drain wire, blocking intra-pair crosstalk and near-field EMI.
Secondary Shield: 95% coverage tinned copper braid (36 x 0.15mm strands), providing >60dB EMI attenuation (100MHz-1GHz) to reject external RFI from industrial machinery, power cables, and wireless systems.
Integrated Grounding System: Shielded connector housing with built-in grounding tab ensures continuous shield-to-port grounding (≤ 0.08Ω ground resistance), eliminating ground loops and signal interference in high-density deployments.
Crosstalk Elimination: Advanced pair stranding and low-dielectric-constant HDPE insulation reduce electromagnetic coupling, enabling stable 10Gbps transmission in dense cable trays (≤ 250 cables/m²)—a key advantage for data center exports.
3. Mechanical & Environmental Durability (Export-Oriented)
Cable Construction:
Insulation: High-purity HDPE (0.95mm thickness) with 1500V AC/DC rating, resistant to moisture, oil, and chemical exposure (compliant with IEC 60754-1).
Jacket: Dual options for global markets:
LSZH (Low Smoke Zero Halogen): Meets IEC 60754-2 (smoke density ≤ 0.1m², toxicity index ≤ 5) and EN 50267-2-1—mandatory for EU, Middle East, and Asian construction projects (LEED/BREEAM certified).
PVC (UL94V-0): Cost-effective, flexible, and compliant with UL 1685—preferred for North American, African, and Latin American markets.
Core Stranding: Filler cord for roundness, tear cord for easy jacket stripping, and aramid yarn for enhanced tensile strength.
Mechanical Ratings:
Tensile Strength: 180N (static), 120N (dynamic) — suitable for international shipping and on-site pulling.
Crush Resistance: 1200N/100mm (1 minute) — withstands packaging and installation impacts.
Bending Radius: 8x cable diameter (static), 12x cable diameter (dynamic) — adaptable to tight spaces in global projects.
Environmental Operating Range:
Temperature: -40°C to 85°C (operating), -55°C to 105°C (storage) — compliant with extreme climates (deserts, arctic regions).
Humidity: 0-95% (non-condensing) @ 40°C — suitable for tropical and coastal export markets.
UV Resistance: Optional UV-stabilized jacket meets ISO 4892-3 (1000h exposure) — for outdoor deployments in Australia, Southeast Asia, and Latin America.
4. Global Compliance & Export Certifications
Performance Certifications: ISO/IEC 11801 Class F, EN 50173-1 Cat7, IEEE 802.3ba, UL/ETL 444, CE (EU), FCC (US), IC (Canada), PSE (Japan), CCC (China), SASO (Saudi Arabia), SONCAP (Nigeria).
Safety Certifications: UL94V-0 (flame retardant), IEC 60332-3-24 (vertical flame), RoHS 2.0 (EU 2011/65/EU), REACH (1907/2006/EC), Proposition 65 (California), INMETRO (Brazil).
Environmental Certifications: LSZH variant meets IEC 60754-2 (low toxicity) and EN 50267-2-1 (low smoke) — aligned with global green building standards.
Engineering Applications & Global Market Advantages
1. Data Centers & Enterprise Backbones
High-Density Racking: Supports 48-port/1U patch panels in hyperscale data centers, enabling 100Gbps short-reach connections for cloud servers and storage arrays—ideal for export to global colocation facilities.
Blade Server Connectivity: Delivers interference-free 40Gbps transmission in dense server racks, reducing cable clutter and improving airflow for international enterprise clients.
Disaster Recovery Networks: Ensures low-latency (≤1ms) data replication between geographically distributed data centers, compliant with global SLA requirements.
2. Industrial Automation & IIoT
Extreme EMI Environments: Dual shielding withstands EMI from VFDs, motors, and power inverters (≤ 1500V/m field strength), supporting PLCs, DCS, and IIoT sensors in manufacturing plants (China, Vietnam, Mexico).
Smart Factory Deployments: Powers industrial IoT ecosystems with PoE++ 90W, eliminating separate power cabling for remote sensors and automation devices—cost-effective for export to industrial hubs.
Outdoor Industrial Installations: UV-resistant jacket and wide temperature range make it suitable for oil refineries, solar farms, and logistics centers in harsh climates.
3. Premium Commercial & Residential (Export Markets)
Luxury Smart Homes: Delivers 8K streaming, 10Gbps gaming, and home automation connectivity in high-end residential projects (Middle East, Asia, North America)—PoE support simplifies IoT device installation.
Corporate Offices & Co-Working Spaces: Supports video conferencing, cloud collaboration, and high-speed internet for multinational companies, with backward compatibility for Cat6A/Cat6 legacy systems.
Professional Studios: Enables 4K/8K video editing, 3D rendering, and audio production in media studios worldwide—zero signal degradation ensures content creation accuracy.
4. Telecom & 5G Networks
5G Small Cell Backhaul: Connects 5G small cells to core networks with 40Gbps capacity, supporting multi-gigabit broadband services in emerging markets (Africa, Southeast Asia).
FTTH Premium Deployments: Powers ultra-high-speed (10Gbps) broadband for luxury residential and business parks in EU, US, and Asian markets.
Cellular Base Stations: Dual shielding protects against RF interference from 5G transmitters, ensuring stable backhaul connectivity for global telecom operators.
Technical Selection Guide for Global Markets
EU & UK: Recommended Configuration – 23AWG LSZH, 0.5m-30m, CE-marked; Key Compliance Requirements – RoHS 2.0, REACH, LSZH (IEC 60754-2), BREEAM.
North America: Recommended Configuration – 23AWG PVC, 0.5m-30m, UL/ETL-listed; Key Compliance Requirements – FCC Part 68, Proposition 65, UL 444.
Asia Pacific: Recommended Configuration – 23AWG LSZH/PVC, 0.5m-30m, PSE/CCC; Key Compliance Requirements – RoHS, CCC (China), PSE (Japan), JIS C 6300.
Middle East & Africa: Recommended Configuration – 23AWG LSZH, UV-resistant, 0.5m-30m; Key Compliance Requirements – SASO, SONCAP, LSZH, ISO 9001.
Latin America: Recommended Configuration – 23AWG PVC, 0.5m-30m, INMETRO; Key Compliance Requirements – RoHS, INMETRO, UL 94V-0.
Technical Validation & Export-Quality Testing
Performance Testing: 100% factory testing with Fluke DSX-12000 cable analyzers (ISO/IEC 11801 Class F compliant), including insertion loss, return loss, and crosstalk (NEXT/FEXT/AXT) — test reports provided in English/Spanish/French.
Mechanical & Shipping Testing: Subjected to ISTA 3A packaging testing (drop, vibration, compression) to ensure durability during international shipping; 10,000 mating cycles and 1000 bending cycles for connector reliability.
Environmental Testing: Passes thermal shock (-40°C to 85°C, 10 cycles), humidity (95% @ 40°C, 1000h), and UV exposure (1000h) — certified for global climate adaptability.
Export Compliance: Batch-level RoHS/REACH testing with certificates of conformity (CoC), material safety data sheets (MSDS), and multi-language labeling (English, Spanish, French, Arabic, Mandarin).
Network Patch Cord Cat8
Oct 23, 202592
Network Rack Wall Mount with Glass Door
Jan 07, 202679
Network Rack Wall Mount 9U
Jan 06, 202675
Network Cable Management Tray
Oct 30, 202573
Network Cable Management Under Desk
Dec 25, 202572